• The PDA10 is a wireless surveying tool kit which is intended to be used in conjunction with PDW30 or PDW90 wireless products. The surveying tool kit comes with two units: a handheld unit and a target unit. Use the pair prior to wireless system installation to demonstrate signal strength throughout the facility or between intended installation locations. The handheld unit may be used standalone after installation in order to determine received signal strength from all of the devices in order to determine new field unit locations or to troubleshoot connectivity issues.

  • Go with the Helios PD2-6200 when you want to display both flow rate and total at the same time from a 4-20 mA output flowmeter. The PD2-6200 can display both flow rate and total in six full digits and can also be configured to display non-resettable grand total. The PD2-6200 can even display open channel flow using its programmable exponent function. The PD2-6200's NEMA 4X enclosure, super bright LEDs, and wide operating temperature range make it perfect for outdoor applications.

     

     

     

    Why you should buy:
    • Large Dual Line Display
    • Displays Flow Rate and Total
    • Analog Input
  • The PDA6420 loop-powered split core AC current transducer converts the AC current flowing through a cable or wire to a 4-20 mA signal and can be set up in the field to handle inputs of 30, 60, or 120 AAC. This nonintrusive device features split core convenience for easy installation and is a cost-effective solution for monitoring load or proof of operation. The current transducer is ideal for monitoring current loads on pumps, driving fans and blowers, and sensing the status of heating coils and lighting. When used for load trending over time, they are effective sensors for predictive maintenance programs. The PDA6420 is a loop-powered device requiring 24 VDC power that can be provided by many Precision Digital meters or by the Precision Digital PDA1024-01 24 VDC power supply.
  • The ConsoliDator+ is a multi-channel controller that is both easy to use and satisfies a wide variety of process display, alarm and control applications. It accepts 4-20 mA inputs, flow meter pulse inputs, digital inputs, Modbus RTU inputs, and displays them both in numeric and bargraph format on a large, 5.7" color display. It can be equipped with multiple relays with user-definable actions, 4-20 mA outputs, digital outputs, Modbus RTU, and Ethernet Modbus TCP/IP protocol communication capabilities. Additionally, the controller is equipped with up to 32 timers that can be used to control many processes or events.

    All this functionality is easily programmed using free software or via the front panel pushbuttons. Choose the model that best suits your application, from monitoring only to fully loaded controllers with an extensive combination of inputs, outputs and communication protocols. The standard product offering is listed in the ordering guide and other models are available for special order.



    PD9000 Panel Mount
    Why you should buy:
    • Display Multiple Inputs on One Screen
    • 4-20 mA & Pulse Inputs
    • Relay & 4-20 mA Outputs
    • Pump Alternation
    • Power the Transmitters
    • Ethernet Modbus TCP/IP Option
  • The PDA0007 ventilation kit consists of two vents and is designed to equalize internal / external pressure and temperature to prevent condensation from building up in the enclosure. Internal baffles within the vents create an airflow pattern that allows air to pass between the inside of the enclosure and the outside environment. The vents are rated UL & CSA Type 4X and IP66. The ventilation kit can also be ordered as a MOD-VENT-P for plastic enclosures and a MOD-VENT-M for steel enclosures. When this is done, the accompanying enclosure will be provided with pre-drilled holes for the vents (Installation is done by the user and the enclosure is sold separately). See ordering information.
  • Go with the Helios PD2-6000 when you need a large display meter to display the 4-20 ma output from any transmitter you might have. The PD2-6000 can display that output in six full digits and will also provide the 24 VDC to power the transmitter. The PD2-6000's NEMA 4X enclosure, super bright, 1.8" (46 mm) high LEDs, and wide operating temperature range make it perfect for outdoor applications. The PD2-6000 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or control applications, including pump alternation control.




    Why you should buy:
  • The Loop Leader PD6600 is a general-purpose, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6604) or feet & inches display (PD6603) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 167°F (-40 to 75°C) operating temperature range. It doesn't matter if it's indoors or out-doors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.


    Why you should buy:
  • The Loop Leader PD6600 is an ATEX, IECEx approved, and UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6608) or feet & inches display (PD6607) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6606
    Why you should buy:
  • The SuperNova PD500 Series of PID Process & Temperature Controllers is a complete line of PID and on/off controllers. Available in popular 1/4, 1/8, and 1/16 DIN sizes, and with a shallow depth behind panel of only 2.5" (63 mm) it is easy to fit into almost any panel, product, or enclosure. Voltage, current (with external resistor), and direct temperature thermocouple and RTD inputs make it an excellent choice for any control application requiring easy to change, visible set points. This modern line of controllers shows the process variable (PV), set value (SV), and manipulated value (output level%, MV) on a striking reverse polarity LCD screen. Indicators for units (˚C, ˚F,%, or none) Auto and manual control modes can be easily changed by holding two buttons, and this is indicated on the front panel to make it easy for operators to know how to use this feature. Main control outputs can be 4-20 mA (SCR), voltage pulse (SSR), or relay outputs. A secondary relay control output is standard, which allow for one or two direction SV control (i.e., heating and cooling). Additional outputs may include two SPST alarm relays and a 4-20 mA retransmit output. Other options include a secondary 4-20 mA input to remotely control the set point, and RS-485 for Modbus communication. A mini-USB port may be used for a direct PC connection to run the SuperNova software for monitoring, programming, and data logging. This USB port is located on the rear behind the panel for PD510 1/16 DIN models, and on the front behind a rubber tab on PD520 and PD530 1/8 and 1/4 DIN models.
    Why you should buy:
    • Auto-Tuning PID Controller
    • Temperature and Process Inputs
    • Heating & Cooling