• The PD6262 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from two (2) analog output (4-20 mA, 0-5 V, 1-5 V, etc.) flowmeters. It displays these signals on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The dual-line display can be used to show both flow rates simultaneously, to alternate between the two inputs showing both the flow rate and total of each, or to show the result of math functions performed on the flow rates and totals. Like all ProVu meters, the PD6262 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6262 dual-input flow rate/totalizer includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The PDA6405 split core AC current transformers convert the high AC current flowing through a cable or wire to a 0-5 AAC output and are available in ranges of 100, 200, 400, 600, and 1000 AAC. These nonintrusive devices feature split core convenience for easy installation and are a costeffective solution for monitoring load or proof of operation. These current transformers are ideal for monitoring current loads on pumps, driving fans and blowers, and sensing the status of heating coils and lighting.
  • Go with the Helios PD2-6001 when you prefer to read level in feet and inches instead of the more common decimal format. This unique display will read up to 99 feet, 11 & 15/16s inches on the upper line. The lower line can display a tag or volume, even from non-linear tanks such as round horizontal ones. The PD2-6001 makes a great outdoor tank side indicator because its display is bright enough to read in direct sunlight and it will operate from -40 to 150°F. The PD2-6001 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or controlling applications, including pump alternation control.



    Why you should buy:
  • The ProtEX+ loop-powered explosion-proof & intrinsically safe meters can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. They can operate down to -40°C and be installed in areas that get as cold as -55°C, however the display will cease functioning. One of the most convenient features is the dual-line display, typically used to display the process variable on the 5-character alphanumeric top display and the units of measure or tag on the 8-character alphanumeric bottom display. Feet and inches models display level in feet and inches on the top display while the 8-digit alphanumeric bottom line may be used to display a tag or custom message. Further enhancing the display on these instruments is a 20-segment bargraph.

    The ProtEX+ carries all major approvals including:

    •  UL Listed as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  CSA Certified as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  ATEX and IECEx Certified as Intrinsically Safe / Explosion-Proof

    Four CapTouch through-glass buttons are available to operate the instrument without removing the cover. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options.

     

     

     

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered
    • Explosion-Proof & Intrinsically Safe
    • Aluminum & Stainless Steel Enclosures
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Bargraph or Feet & Inches Display
    • Discrete and Analog Output Options
  • The PDA1004 four relay external expansion module adds four 3 amp Form A (SPST) relays to any ProVu meter. It can be configured for functions similar to the ProVu onboard relays and can be added at any time.

  • The ProtEX+ loop-powered explosion-proof & intrinsically safe flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. They can operate down to -40°C and be installed in areas that get as cold as -55°C, however the display will cease functioning. One of the most convenient features is the dual-line display, typically used to display the flow rate on the 5-character alphanumeric top display and flow total, flow grand total, or tag on the 8-character alphanumeric bottom display. The top display uses 12-segment, and the bottom display uses 14-segment alphanumeric characters for clear indication of tags, units, or alarm messages. Further enhancing the display on these instruments is a 20-segment bargraph.

    The ProtEX+ carries all major approvals including:

    •  UL Listed as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  CSA Certified as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  ATEX and IECEx Certified as Intrinsically Safe / Explosion-Proof

    Four CapTouch through-glass buttons are available to operate the instrument without removing the cover. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

     

     

     

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered Rate / Totalizer
    • Display Rate & Total Simultaneously
    • Explosion-Proof & Intrinsically Safe
    • Aluminum & Stainless Steel Enclosures
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Discrete and Analog Output Options
  • The PDA1011 analog output external expansion module adds an additional 2 analog outputs to any dual-input ProVu meter or ProVu Modbus® scanner (i.e. PD6060, PD6080, PD6081, PD6088, PD6089, PD6262, or PD6363). It can be configured for functions similar to the ProVu onboard analog output and can be added at any time.

  • The PDA1044 digital I/O external expansion module adds four digital inputs and four digital outputs to any ProVu meter. Up to two digital I/O expansion modules may be added to each meter, for a total of eight (8) additional digital inputs and outputs per meter. External digital inputs function similarly to the F4 digital input on most ProVu models. They can be configured to trigger events (e.g. acknowledge/reset alarms, reset max and/or min values, disable/enable all output relays), provide specific menu access, or mimic front keys. Digital outputs can be used to remotely monitor alarm relay states or the states of a variety of actions and functions executed by the meter.

  • The Vantageview PD6700 is one of Precision Digital's most advanced and feature-packed plastic, field-mounted, loop-powered indicators. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines. The PD6700 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. The display has a five digit upper display, a seven alpha-numeric character lower display, and comes with a backlight standard. Two features that really make the PD6700 stand out are its wide viewing angle display and SafeTouch® through-window buttons. These buttons allow the meter to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.

    Why you should buy:
    • NEMA 4X/IP65 Enclosure
    • Loop-Powered
    • Level Indication Bargraph Display