- ModbusĀ® RTU Master, Slave, or Snooper Mode
- Poll and Display up to 16 Process Variables
- Large Dual-Line 6-Digit Display, 0.60" & 0.46"
- SunBright Display Standard
- 32-Point, Square Root, or Exponential Linearization
- Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, & More
- Type 4X, NEMA 4X, IP65 Front
- Universal 85-265 VAC, or 12-24 VDC Input Power Models
- 12-36 VDC/12-24 VAC Power Option
- Onboard USB and ScanView Programming Software
** NEW IMPROVED WEB STORE! | All users must register for a new account. | Register now > **
BUY ONLINE TO SAVE TIME AND INCREASE ORDER ACCURACY!
- Accessories
- Annunciators & Scanners
- Calibrators, Signal Isolators, Splitters, & Generators
- Control Stations
- Custom Enclosure Assembly
- Demo Units
- Digital Panel Meters
- Enclosures
- Explosion-Proof
- Field-Mount Indicators
- Industrial Wireless
- Intrinsically Safe
- Large Display
- Light/Horn
- Loop-Powered Meters
- Modbus Displays
- Modifications
- Multi-Channel Controllers
- Process Value Alarm Enclosure Assembly
- Sun Hoods
- Subpanel Wiring Assembly
- Temperature Controllers
- Level
- Level (Feet & Inches)
- Process
- Pressure
- Temperature
- Flow Rate/Totalizer
- Pump Control
- Chemical Bulk Storage
- Strain Gauge
- Load Cell
- Hazardous Area
- Industrial Wireless
- Batch Control
- PID Control
- Modbus
- Annunciator
- Calibration
- Data Logging
- Signal Conditioning
- Signal Generation
- Signal Isolating
- Signal Splitting
- High Current
- Speed
- Weight
ProVu Decimal Display Modbus Scanner with Dual Analog Inputs
Models in stock
from $748.00
The ProVu PD6080 Super Snooper Modbus scanner is a multi-purpose display and controller capable of scanning up to 16 Modbus process variables and accepts two analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of an easy-to-read and conveniently located remote display. As a master, the PD6080 can read up to 16 Modbus registers on up to 16 Modbus devices and automatically alternate each of these process variables (PVs) on the dual-line display along with a unit and tag for each. In snooper mode, the PD6080 can read any Modbus variable being polled by a master, which allows you to easily add a display into an existing Modbus network. Like all ProVu meters, the PD6080 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Powerful math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.
- Modbus Input
- Dual Analog Input
- USB Programming
TheĀ ProVuĀ PD6080 Super Snooper ModbusĀ® scanner is a multi-purpose display and controller capable of scanning up to 16 Modbus process variables and accepts two analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of an easy-to-read and conveniently located remote display. As a master, the PD6080 can read up to 16 Modbus registers on up to 16 Modbus devices and automatically alternate each of these process variables (PVs) on the dual-line display along with a unit and tag for each. In snooper mode, the PD6080 can read any Modbus variable being polled by a master, which allows you to easily add a display into an existing Modbus network. Like allĀ ProVuĀ meters, the PD6080 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Powerful math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.
Inches (mm)
Product Information (3)
Modbus Register Tables (1)
ScanView software allows for the programming and monitoring of one ProVu, ProtEX-MAX, or Helios Modbus Scanners. Use ScanView to program, monitor, and datalog using a PC. The PVs and math channels may be selected to display on the monitoring screen independently, and the monitoring screen can be customized so each has a configurable unit and tag. Even the display number colors may be changed. All 16 PVs, math channels, and their units and tags may be logged. The data is logged on the PC, and is available for use in common tools like Microsoft Excel. All configuration data can be saved to a file for future use.
Installation of ScanView software is required for technical support services to be provided for ProVu, ProtEX-MAX, or Helios Super Snoopers Modbus Scanners.
IMPORTANT!
Uninstall previous versions before downloading and running the latest version.

ScanView software can be installed on any Microsoft Windows 10/11 computer. Connect one end of a USB cable to the scanner and the other end to the computer. The scanner is powered via USB, so there is no need to wire anything before programming it. USB connection is intended for configuration purposes only.

Microsoft Windows 10/11
Onboard USB (firmware version 4.0 or higher), RS-232 Adapter, or RS-485 Adapter
1-247
1-247, 256-259 for on-board Current & Voltage inputs
300 bps to 19,200 bps; selection must match the baud rate selected in the meters
Dependent on system and scanner settings
Configure scanner settings one scanner at a time
Save as CSV file format
Save as MVP file format or print configuration
Modbus RTU
2.1.3